COLD AMP FREEZER ROOMS BOOSTING ZAMBIA''S GROWTH

Cold Aisle and Hot Aisle in Computer Rooms

Cold Aisle and Hot Aisle in Computer Rooms

Cold Aisle: Rows of racks face each other, forming a corridor where cool air is directed. The hot aisle /cold aisle data center layout was originated by IBM in 1992 and it is one of the oldest ways to save energy in the data center. When implemented correctly, they improve efficiency, reduce energy consumption, extend equipment life, and enhance overall reliability. So we look to factors other than the economics of efficiency to evaluate the relative merits of the two. And like choosing between Marvel and DC, you must pick a side: Hot Aisle Containment (HAC) or Cold Aisle Containment (CAC). The system simply aligns server fronts (air intakes) toward a shared cold aisle, and backs (exhausts) toward a shared hot aisle.

Read More
Methods for sealing off cold aisles in computer rooms

Methods for sealing off cold aisles in computer rooms

This involves sealing off the aisle so that cold air does not mix with warm air within the data center. By sealing out moisture, the total available cooling can be more effectively used to cool the computer servers' heat load, which is 100% sensible (no moisture content). Beyond implementing basic measures such as sealing moisture out of the data center and improving air flow, aisle containment to prevent the mixing of hot and cold air stands out as a method that can dramatically reduce energy costs, minimize hot spots and improve the carbon footprint of data. Cold aisle containment (CAC) serves as a fundamental airflow management strategy in modern Data Centres, optimising cooling efficiency and enhancing overall performance.

Read More
Are outdoor fiber optic cold splices prone to failure

Are outdoor fiber optic cold splices prone to failure

Handling and splicing fiber optic cables in cold weather also present challenges. Here's how cold weather can affect fiber optic cables and what measures can be taken to mitigate these effects: Temperature fluctuations can cause the materials in the cable, including the fiber, cladding, and outer sheath, to expand and contract. fiber - Do low temperatures cause problems installing new optical wiring or fixing broken optical cables by splicing? - Network Engineering Stack Exchange Do low temperatures cause problems installing new optical wiring or fixing broken optical cables by splicing? One of our supplier reported big. Intrinsic factors, such as the refractive index of the fiber, are those that are inherent to the fiber itself.

Read More
Cold aisle immersion liquid cooling system for computer room cabling systems

Cold aisle immersion liquid cooling system for computer room cabling systems

The cooling systems technologies we install can be used in buildings housing smaller server rooms to hyperscale data centres and include free-air cooling as well as advanced liquid cooling systems. Clients expect us to not only improve their cooling and resilience (N+X) but also to reduce their total cost of ownership (TCO) and energy usage by 50%. Whether the facility has low or high density racks or a combination, it is essential to install the most appropriate data centre cooling systems to tackle the heat generated from critical IT servers, management the environmental impact of the data centre and. The Server Room Environment range includes precision air conditioning units up to 250kW, low, medium and high-density rack cooling systems up to 70kW.

Read More
What tools are used for cold joints

What tools are used for cold joints

To repair a cold joint in concrete, you will need a set of essential tools, including a wire brush, chisel or grinder, masonry drill, bonding agent, concrete patching compound, trowel, and protective gear. Specific materials are required such as water, sand, cement, and any necessary reinforcement. Saw-cutting and concrete re-pour to increase integration between fresh and set batches. The term "cold" is used because the two concrete layers are not bonded properly, which can result in a weakened. If these joints aren't handled right, the bond between the two can weaken, letting moisture in and causing all kinds of Mischief with your project.

Read More

Get In Touch

Connect With Us

📱

South Africa (Sales & Engineering HQ)

+27 10 247 8396

📍

Headquarters & Manufacturing

Unit 7, Summit Place, 21 Summit Rd, Midrand, Johannesburg, 1685, South Africa