DECODE LABEL AND OID VALUES FOR SWA AND SMA

Normal attenuation values ​​for fiber optic patch cords

Normal attenuation values ​​for fiber optic patch cords

The ANSI/TIA/EIA-568-B standards designate the allowable attenuation coefficients for the different cable types along with the loss for fixed connectors as 0. This level of testing consists of link attenuation testing, link length, and a pola ity check. They are manufactured and tested in compliance with TIA 604 (FOCIS), IEC 61754 and YD/T industry standards. These fiber optic cables have been built to exceed industry standards tested for insertion loss and reflectance on within UL certified OFNR (Riser) rated jacket with Kevlar yarn, and are factory terminated. ITU-T and IEC have implemented multiple changes to their respective documents regarding Single Mode Fiber (SMF) since the last IEEE document was published. In the test report for a fiber cable, you may often see some data related to fiber insertion loss (IL) and return loss (RL), but do you know what insertion loss and return loss actually mean? How do the values of IL and RL impact the quality of the fiber cable? Are higher values better, or lower.

Read More
Standard values ​​for grounding testing of distribution boxes

Standard values ​​for grounding testing of distribution boxes

26 mm 2 (10 AWG) ground wire must be used, and in all other markets a 6 mm 2 must be used. The recommended practices in this document are intended to provide explanations of how electrical systems operate. This Grounding Standard describes factors affecting the ground resistance and the method of measuring ground resistance of Distribution installations. Today, we're diving deep into the world of distribution box grounding, breaking down the standards, and shining a light on those sneaky mistakes that even experienced electricians sometimes make. Whether you're a seasoned pro or just starting out, this comprehensive guide will give you practical. The LPS designer and the LPS installer should select suitable types of earth electrodes and should locate them at safe distances from entrances and exits of a structure and from the external conductive parts in the soil, such as cables, metal ducts, etc.

Read More
Standard values ​​for optical fiber transmission loss

Standard values ​​for optical fiber transmission loss

For multimode fiber, the loss is about 3 dB per km for 850 nm sources, 1 dB per km for 1300 nm. To be able to judge whether a fiber optic cable plant is good, one does a insertion loss test with a light source and power meter and compares that to an estimate of what is a reasonable loss for that cable plant. The estimate, called a "loss budget" is calculated using typical component losses for. Fiber optic loss, also known as optical attenuation, refers to the light loss between the transmitter and receiver. This type of testing is the most accurate testing available and is the most accurate characterization of the fiber optic system's apability. Fiber optic loss is one of the most fundamental parameters in optical network engineering, yet it is often misunderstood as a purely theoretical value used only during design calculations.

Read More
How to read the label on an optical module

How to read the label on an optical module

Generally, the label of an optical module provides the following information: manufacturer, serial number, speed, center wavelength, mode (single-mode/multimode), and transmission distance. To determine if your SFP (Small Form-factor Pluggable) module is single mode or multimode, you can look for specific markings or labels on the module itself. Typically, single mode SFP modules are labeled as "SM" or "single mode," while multimode modules may be labeled as "MM" or "multimode. During use, reading optical module information helps understand its real-time operating status, enabling faster troubleshooting of link abnormalities.

Read More
SMA Multimode Fiber Customization

SMA Multimode Fiber Customization

Depending on the specific needs of the user, SMA fiber optic cables can be customized in terms of cable length, connector types, and jacket materials. Thorlabs offers multimode circular-core step-index fiber optic patch cables with SMA905 (straight ferrule) connectors on both ends. A 1000 μm core diameter with a bonded hard polymer 1035 μm cladding supports 500-1100 nm operation. Choose from SC to SMA, SMA to ST and LC to SMA Fiber Optic Cables, multimode, duplex. Please use the check boxes and sliders to select certain features and narrow down your search to the specifications you need.

Read More

Get In Touch

Connect With Us

📱

South Africa (Sales & Engineering HQ)

+27 10 247 8396

📍

Headquarters & Manufacturing

Unit 7, Summit Place, 21 Summit Rd, Midrand, Johannesburg, 1685, South Africa