MEASUREMENT OF INSULATION RESISTANCE IR – PART 2

Relay protection resistance measurement

Relay protection resistance measurement

To check the relay coil's resistance, take the multimeter you have and place it in the ohmmeter (Ω) setting and place the probe leads of the multimeter on the 2 terminals of the relay's coil. The testing and verification of relay protection devices can be divided into four groups: Type tests are needed to prove that a protection relay meets the claimed specification and follows all relevant standards. Protective Relays - Technical Seminar Nov 2016 - Copyright: IEEE 2 Abstract: Protective relays and devices have been developed over 100 years ago to provide "lastline"of defense for the electrical systems.

Read More
Grounding resistance value of the capacitor in the distribution box

Grounding resistance value of the capacitor in the distribution box

Grounding of the units: Attach a ground wire from one of the threaded studs (A) at the bottom of the housing, to the mounting plate (B). Basically, the idea of bob-smith termination is to provide a sink for common-mode noise that may transfer from the PHY side to the connector side. The National Electrical Code (NEC) defines system ground as a connection to ground from one of the current-carrying conductors of an electrical power system or of an interior wiring system, whereas an equipment ground is defined as a connection to ground from one or more of the noncurrent-carrying. The information provided in this document contains general descriptions, technical characteristics and/or recommendations related to products/solutions. Hattan Cosj 1 güç katsayısı ile iletilen P1, S1 ve Q1 güçleri yerine Cosj 2 güç katsayısı altında P1, S2 ve Q2 güçlerini iletmek için Qc kadar bir kompanzasyon gücü gereklidir.

Read More
Earthquake Resistance of Cable Trays in Africa

Earthquake Resistance of Cable Trays in Africa

Cable tray and conduit systems have an excellent earthquake performance record. This has been evidenced at over 70 power and industrial facilities in 14 past major earthquakes, and is reinforced by shake table test data and detailed analyses. Earthquakes and seismic events can cause severe damage to electrical infrastructure, including cable trays, leading to outages and even safety hazards. Seismic forces are generated by the movement of the Earth's crust during an earthquake. A method is developed for utilizing this data in defensible, simple seismic qualification criteria and configuration controls. During an earthquake, cable trays are exposed not only to gravity loads and normal service loads, but also to lateral movement, vertical acceleration, vibration, and building drift.

Read More