MICRONET FOR COMPUTER الشبكة المصغرة للكمبيوتر

Power Supply Unit Model for Computer Room

Power Supply Unit Model for Computer Room

When motherboard and graphics-card manufacturers started powering CPUs and GPUs from separate 12-volt connectors, many older power supplies were still designed to put out a substantial portion of their amperage to 5-volt and eve. That led to widespread advice and articles recommending wildly exaggerated power-supply ratings to cover. Power supplies, as we know them in desktop PCs, go all the way back to the original IBM PC. 80 Plus is a power-supply certification program that guarantees a minimum of 80% efficiency across a wide variety of loads, with different levels offering increased energy savings via reduced PSU waste heat.

Read More
Cold aisle immersion liquid cooling system for computer room cabling systems

Cold aisle immersion liquid cooling system for computer room cabling systems

The cooling systems technologies we install can be used in buildings housing smaller server rooms to hyperscale data centres and include free-air cooling as well as advanced liquid cooling systems. Clients expect us to not only improve their cooling and resilience (N+X) but also to reduce their total cost of ownership (TCO) and energy usage by 50%. Whether the facility has low or high density racks or a combination, it is essential to install the most appropriate data centre cooling systems to tackle the heat generated from critical IT servers, management the environmental impact of the data centre and. The Server Room Environment range includes precision air conditioning units up to 250kW, low, medium and high-density rack cooling systems up to 70kW.

Read More
Methods for sealing off cold aisles in computer rooms

Methods for sealing off cold aisles in computer rooms

This involves sealing off the aisle so that cold air does not mix with warm air within the data center. By sealing out moisture, the total available cooling can be more effectively used to cool the computer servers' heat load, which is 100% sensible (no moisture content). Beyond implementing basic measures such as sealing moisture out of the data center and improving air flow, aisle containment to prevent the mixing of hot and cold air stands out as a method that can dramatically reduce energy costs, minimize hot spots and improve the carbon footprint of data. Cold aisle containment (CAC) serves as a fundamental airflow management strategy in modern Data Centres, optimising cooling efficiency and enhancing overall performance.

Read More
Can fiber optic cables in a computer room be spliced ​​in the middle

Can fiber optic cables in a computer room be spliced ​​in the middle

This process is essential in telecommunications for extending network reach or repairing damaged sections without replacing entire cables. Fiber cable splicing is a critical step in building reliable fiber optic networks. Whether in data centers, telecom rooms, or outdoor FTTx deployments, proper splicing inside a fiber enclosure ensures low signal loss, long-term stability, and easy maintenance. This is where fiber optic cable splicing—the process of creating a permanent, high-performance join between two fiber ends—becomes critical.

Read More

Get In Touch

Connect With Us

📱

South Africa (Sales & Engineering HQ)

+27 10 247 8396

📍

Headquarters & Manufacturing

Unit 7, Summit Place, 21 Summit Rd, Midrand, Johannesburg, 1685, South Africa