ZHENJIANG SIEMENS BUSBAR TRUNKING SYSTEMS CO.

Low-voltage overhead busbar trunking

Low-voltage overhead busbar trunking

A Busbar Trunking System (BTS) is a factory-built low-voltage power distribution assembly verified under IEC 61439-6. It uses prefabricated busbar sections, joints, tap-off units, and accessories to distribute power safely with defined current ratings and short-circuit withstand. Our busbar trunking systems provide an efficient, safe and flexible alternative to cable, and a modular switchboard can meet your needs with flexibility and reliability. Types: Benefits: Discover how to achieve fast and reliable cabling thanks to Easy 9 comb busbar.

Read More
High-voltage busbar trunking inspection

High-voltage busbar trunking inspection

Daily Inspection: Visually inspect the busbars for any abnormalities such as cracks, rust, deformation, or discoloration. Dielectric testing ensures the insulation of busbars can withstand the operating voltage and environmental conditions without breaking down. The purpose of this method is to verify the functionalities of a Metal Enclosed Busb ar. The test shall be carried out according to IEC 60068-2-2 Test Bb, at a temperature of 70 °C, with natural air circulation, for a duration of 168 h (7 days) and with a recovery of 96 h (4 days). Our team utilises fully calibrated equipment for inspecting, servicing, and conducting electrical tests and diagnostics to address busbar performance issues. Earth tester Multimeter I Continuity tester Megger Tester Technician's tools Calibration.

Read More
High-voltage switchgear early warning busbar

High-voltage switchgear early warning busbar

Non-contact infrared sensors continuously monitor busbar temperature from a safe distance within cabinets, avoiding physical contact or complex insulation requirements. Electrical failures are caused by a number of different factors, including: Continuous thermal monitoring technology enables critical MV switchgear joints and busbar connections to be monitored in real-time. Thermal monitoring locations include: Eaton Exertherm CTM solution for MV switchgear. Such fluctuations can eventually lead to insulation aging, poor contact, and even major fire. Busbars have typically been left without dedicated protection, from the following reasons: It is a fact that the risk of a short circuit happening on modern metal clad equipment is insignificant, but it cannot be completely dismissed. High-impedance voltage differential protection is a solution to the challenge of CT saturation during external faults, as the high impedance of the relay forces the error current due to the saturated CT back through the CTs instead of the relay operating coil.

Read More

Get In Touch

Connect With Us

📱

South Africa (Sales & Engineering HQ)

+27 10 247 8396

📍

Headquarters & Manufacturing

Unit 7, Summit Place, 21 Summit Rd, Midrand, Johannesburg, 1685, South Africa